Key result
Evolut 26-mm linked to ~15-point lower rate of high gradients vs Sapien 23-mm in small annuli.
Why the study?
Patients with small aortic annuli (SAA) are prone to higher post-TAVR transvalvular gradients and prosthesis-patient mismatch, and valve selection commonly involves choosing between the 26-mm Medtronic Evolut 2 and the 23-mm Edwards Sapien 3.
Does TAVR with the 26-mm Medtronic Evolut 2 valve reduce post-procedural transvalvular gradients and prosthesis-patient mismatch compared with the 23-mm Edwards Sapien 3 valve in patients with small aortic annuli?
Cohort (n=1,162)
Yes
Does TAVR with the 26-mm Medtronic Evolut 2 valve reduce post-procedural transvalvular gradients and prosthesis-patient mismatch compared with the 23-mm Edwards Sapien 3 valve in patients with small aortic annuli?
Answers are grounded in this paper and cite their sources.
In patients with small aortic annuli undergoing TAVR, the 26-mm Medtronic Evolut 2 valve yields significantly lower transvalvular gradients and rates of prosthesis-patient mismatch than the 23-mm Edwards Sapien 3 valve, though 1-year clinical outcomes are similar.
BACKGROUND: Patients with small aortic annuli (SAA) are prone to higher post-transcatheter aortic valve replacement (TAVR) transvalvular gradients and development of prosthesis-patient mismatch (PPM). In many patients with SAA, the choice of TAVR valve commonly involves choosing between the 26-mm Medtronic Evolut 2 (ME26) or the 23-mm Edwards Sapien 3 valve (ES23). We compared echocardiographic and clinical outcomes in patients with SAA undergoing TAVR with either valve. METHODS: We queried the Providence St. Joseph Health Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry database for patients undergoing TAVR with either the ES23 or ME26 between July 2015 and December 2018 at 11 hospitals. Post-TAVR echocardiographic and clinical results in-hospital, at 1 month, and at 1 year were examined. High gradient (HG) was defined as mean gradient (MG) ≥20 mm Hg. RESULTS: We identified 1162 patients with SAA undergoing TAVR with either the ME26 (n = 233) or ES23 valve (n = 929). Baseline characteristics between groups were similar. At 1 month, the ME26 was associated with a lower MG than the ES23 (7.7 ± 4.7 mm Hg vs 13.1 ± 4.9 mm Hg; P<.001) and moderate or severe PPM (11% and 3% vs 27% and 13%; P<.001). Occurrence of HG at 1 year was lower with the ME26 valve vs the ES23 valve (0% vs 15%; P<.001). In-hospital and follow-up clinical outcomes to 1 year were similar for both groups. CONCLUSION: TAVR in SAA with the ME26 is associated with lower incidence of HG or PPM compared with the ES23. While clinical outcomes at 1 year were similar, the long-term implications of these findings remain unknown.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2022) conducted a cohort in Small aortic annulus undergoing transcatheter aortic valve replacement (TAVR) (n=1,162). 26-mm Medtronic Evolut 2 valve (ME26) vs. 23-mm Edwards Sapien 3 valve (ES23) was evaluated on High gradient (mean gradient >=20 mm Hg) at 1 year (p=<.001). The 26-mm Evolut 2 valve had lower 1-year high gradient rates and 1-month mean gradients than the 23-mm Sapien 3 in small aortic annuli.