Key result
TAVR with a 34-mm self-expanding valve achieved technical success in 100% (4/4) of LVAD patients with severe AR, though 1 patient had persistent mild-to-moderate PVL.
Why the study?
Invasive treatment options for patients with end-stage heart failure and an LVAD who develop severe AR are limited, and data on outcomes after TAVR in this population are scarce.
Is transcatheter aortic valve replacement a feasible treatment for severe aortic regurgitation in patients with a left ventricular assist device?
Case Report (n=4)
Is transcatheter aortic valve replacement a feasible treatment for severe aortic regurgitation in patients with a left ventricular assist device?
Answers are grounded in this paper and cite their sources.
TAVR with a 34-mm self-expanding valve was technically successful in 4 consecutive LVAD patients with severe aortic regurgitation, demonstrating feasibility while highlighting challenges like paravalvular leak requiring valve-in-valve rescue.
BACKGROUND: There are limited invasive treatment options for patients with end-stage heart failure and left ventricular assist device (LVAD) who develop severe aortic valve regurgitation (AR). One option for such patients is transcatheter aortic valve replacement (TAVR). There are limited data on outcomes of patients with LVAD who receive TAVR for severe AR. We present a series of 4 consecutive patients with LVAD who underwent TAVR for severe AR. METHODS AND RESULTS: This is a retrospective chart review of 4 consecutive patients with LVAD who underwent TAVR for severe AR. All 4 patients underwent TAVR with a 34-mm self-expanding valve (Medtronic). One patient received a 29-mm balloon-expandable valve (Edwards Lifesciences) within the self-expanding valve (SEV) to postdilate the SEV and minimize paravalvular leak (PVL). All 4 procedures were technically successful. The patient who received rescue valve-in-valve TAVR continued to have persistent mild to moderate PVL. CONCLUSION: Although technically challenging, TAVR is a feasible option for carefully selected LVAD patients with severe AR. Procedural issues to consider include oversizing the transcatheter heart valve (THV) while being cognizant of the risks of annular rupture and valve dislocation, anticipating and avoiding ventricular migration of the THV and being ready to postdilate the THV if necessary, to limit hemodynamically significant PVL.
No takes yet. Share an insight, caveat, or question.
Ethan C Korngold (2022) conducted a case report in End-stage heart failure with left ventricular assist device (LVAD) and severe aortic regurgitation (AR) (n=4). Transcatheter aortic valve replacement (TAVR) with a 34-mm self-expanding valve was evaluated on Technical procedural success. TAVR with a 34-mm self-expanding valve achieved technical success in 100% (4/4) of LVAD patients with severe AR, though 1 patient had persistent mild-to-moderate PVL.
Synapse has enriched 10 related papers. Consider them for comparative context: