Answers are grounded in this paper and cite their sources.
Battery thermal management is crucial for the safety and performance of lithium-ion batteries. Dual-evaporator loop heat pipe (DE-LHP) is a passive cooling device, but the coupled heat transport mechanism is not fully understood. Therefore, this study aimed to propose an integrated analytical framework linking temperature distribution, heat flow rate, thermal resistance, and thermophysical properties, as well as to estimate the mass flow rate of the working fluid and latent/sensible heat transport. The framework was applied to a previously reported experimental dataset obtained under quasi-steady conditions with five inter-cell spacing configurations. Consistent with the previously reported favorable thermal response of the 18 mm configuration, the analytical framework showed that the spacing had a battery-to-ambient thermal resistance of 9.23 K W −1 and the highest estimated working-fluid mass flow rate of 2.18 × 10 −6 kg s −1 under quasi-steady conditions. The model-derived thermodynamic energy partition further indicated that approximately 88–89% of the transported heat was associated with the latent component and 11–12% with the sensible component. These values represented analytical energy-partition indicators and were not interpreted as independent evidence of phase-change dominance. In line with the analysis, the proposed framework provided a quantitative basis for interpreting the coupled thermal and thermo-fluid relationships associated with heat transport in DE-LHP-based BTMS.
No takes yet. Share an insight, caveat, or question.
Hadi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: