Answers are grounded in this paper and cite their sources.
Small hydrogen leaks from pipes can ignite as horizontal jet flames. This study measured how pipe size affects their shape and temperature field. Hydrogen was released through pipes of 3.175 and 6.35 mm outer diameter at 2–5 L min −1 and supply pressures of 0.2–0.8 MPa; the flames were photographed and temperatures recorded with 18 thermocouples. Pipe size controlled the flame shape: the larger-pipe flame bent strongly upward and grew longer and taller with flow, whereas the smaller-pipe flame stayed nearly horizontal, with its height constant at about 60 mm. At equal flow, buoyancy relative to jet momentum was about 62 times higher for the larger pipe. The larger pipe heated a wide, rising region, whereas the smaller pipe carried concentrated heat farther along the jet axis. Published flame-size correlations did not place both pipes on one curve. The data provide a reference for assessing small leaks.