To support the Phase II ultracold neutron source at China Spallation Neutron Source, a sub-Kelvin cryogenic system capable of maintaining a 70 mm × 70 mm × 1000 mm superfluid helium converter below 0.7 K was designed and thermally analyzed. The system integrates a 1.4 K 4 He loop, a 0.5 K 3 He loop, and an ultrapure 4 He loop. Thermal loads from structural conduction, radiation, residual gas conduction, and process cooling were evaluated. The optimal 3 He inlet pressure was determined as 95 000 Pa to achieve balanced thermal load distribution. A spiral heat exchanger with a required tube length of 191 mm was designed for 2.6 K precooling. The minimum required 3 He– 4 He interfacial heat transfer area was calculated as 456 cm 2 . A porous alumina superleak achieved a 3 He/ 4 He isotopic ratio of 10 −10 . Four GM cryocoolers satisfy the total cooling demand of 89.49 W at 45 K and 1.958 W at 3.05 K.