Randomized trial evaluates cryogenic performance of SHP20 in superconducting accelerators, indicating effective cooling capabilities.
The SHP20, a 2 K superfluid helium cryoplant, was developed to test various cryogenic components of superconducting radiofrequency (SCRF)-based linear accelerators. Critical components of the 2 K coldbox include a 4.5 K saturated liquid helium (LHe) bath, a 2 K saturated LHe bath, a plate-fin type Joule-Thomson (JT) heat exchanger (HEX), bellow-sealed cryogenic control valves, and a liquid nitrogen (LN2)-cooled thermal shield. The developed SHP20 is integrated with the indigenous helium liquefier “LHP50”, and its cryogenic performance was tested during round-the-clock operation. Sub-atmospheric helium is compressed using a vacuum pump. The multiple switching operations between the 4.5 K standby mode and the 2 K mode were tested. The measured static heat load to the 2 K LHe bath is approximately 0.5 W. The current article briefly describes the development of the SHP20 coldbox and its components, and presents the initial test results.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2025) studied this question.