In this study, the effect of chute slope on energy dissipation has been investigated. For this purpose, a general non-dimensional relationship was developed. Then, a series of experimental tests were conducted with physical models using six different bed slopes (16.4, 20.6°, 22.6°, 25°, 28.7°, and 35°) and two different uniform roughness heights (3.38 and 38.1 mm). A total of 120 tests were conducted with flow discharges ranging from 4 to 45 ls−1. Results show that, compared with the smooth bed, nearly 7–51% of the flow energy was dissipated on the roughened bed chute. Energy dissipation per unit length of the chute and the ratio of energy dissipation to upstream energy increased by 80% and 95%, respectively. Maximum energy dissipation occurred at a slope of 16.4° within the tested range of slopes, and the minimum energy dissipation occurred at 35°. A relationship was developed to predict energy dissipation for this type of chute, and the results were compared with those of previous works.
No takes yet. Share an insight, caveat, or question.
Beiranvand et al. (2026) studied this question.