Key result
Y-incision aortic root enlargement yields a ~7 mmHg mean gradient and LVH regression at 6 months.
Why the study?
Aortic valve replacement with small-diameter prostheses in patients with a narrow aortic annulus carries a high risk of prosthesis-patient mismatch, persistent heart failure symptoms, and difficulty performing subsequent valve-in-valve procedures, necessitating a continued search for effective surgical enlargement techniques.
Does the Y-incision aortic root enlargement technique allow implantation of a larger aortic valve prosthesis and achieve low transprosthetic pressure gradients in a female patient with severe aortic stenosis and a narrow aortic annulus?
Case Report (n=1)
No
Does the Y-incision aortic root enlargement technique allow implantation of a larger aortic valve prosthesis and achieve low transprosthetic pressure gradients in a female patient with severe aortic stenosis and a narrow aortic annulus?
This case report demonstrates that the Y-incision aortic root enlargement technique enables implantation of a larger biological prosthesis up to five sizes larger than the native narrow aortic annulus, resulting in a low postoperative mean gradient of 7 mm Hg at 6 months and facilitating potential future valve-in-valve procedures.
Answers are grounded in this paper and cite their sources.
May support feasibility in narrow-annulus AVR; leaves open efficacy and safety in larger cohorts.
Aortic valve (AV) stenosis is a significant public health issue; it is currently the most common valvular heart disease in the adult population. In Russia, surgical correction of AV disease is the second most common cardiac surgery procedure, ranking only behind coronary artery bypass grafting. Prosthesis size selection is based on the diameter of the surgical aortic annulus. An annulus with a diameter of up to 21 mm is considered narrow. Given the relative surgical complexity of aortic root enlargement, less invasive alternatives exist—such as the implantation of small-diameter prostheses, sutureless bioprostheses, or prostheses with a dynamic adaptive frame. In such cases, some authors employ aortic valve leaflet bioprosthetic reconstruction using autologous or xenogeneic pericardium (neocuspidalization). Aortic valve replacement with small-diameter prostheses carries a high risk of patient-prosthesis mismatch, resulting in suboptimal clinical outcomes for aortic valve disease. A further challenge is the difficulty of performing subsequent endovascular “valve-in-valve” re-replacement. In the postoperative period, patients with a narrow aortic valve annulus may experience a mismatch between the prosthesis size and the patient’s anatomy (prosthesis-patient mismatch), a condition associated with high transvalvular pressure gradients and persistent clinical signs of heart failure following surgical correction of the valvular defect. This situation is suboptimal and necessitates a continued search for the most effective surgical treatment methods. The aim of the study To report a clinical case involving the use of the Y-incision technique for aortic root enlargement in a patient with a narrow aortic valve annulus. Conclusion The aortic root enlargement technique utilizing the Y-incision method offers several advantages over other posterior aortic root enlargement techniques: it enables the implantation of prostheses up to five sizes larger than the native aortic valve annulus, preserves the structural integrity of the central fibrous body, and allows for minimal transprosthetic pressure gradients. Furthermore, the enlargement of the aortic root and the implantation of a larger prosthesis facilitate the potential for performing a “valve-in-valve” endovascular aortic valve replacement procedure, should the need arise.
No takes yet. Share an insight, caveat, or question.
Расимович et al. (2026) conducted a case report in Aortic valve stenosis with a narrow aortic annulus (n=1). Y-incision aortic root enlargement with synthetic patch and biological aortic valve replacement was evaluated on Mean transprosthetic pressure gradient at 6 months (mmHg). Y-incision aortic root enlargement during aortic valve replacement in a patient with a narrow annulus achieved a mean transprosthetic gradient of 7 mmHg and regression of LV hypertrophy at 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: