Answers are grounded in this paper and cite their sources.
This article describes the author's modification of the parallel wire technique – the “parallel loop technique” – designed to overcome resistant stenoses of dialysis vascular access. The relevance of the problem is driven by the need for long-term functioning of the arteriovenous fistula in patients with chronic kidney disease (CKD). Outflow vein stenosis is one of the main causes of access dysfunction, and standard balloon angioplasty is not always effective in cases of severe fibrosis. Two clinical cases are presented demonstrating a stepwise escalation of mechanical impact. In the first case, standard balloon angioplasty and the use of two parallel 0.035" guidewires made it possible to concentrate pressure and achieve an optimal angiographic result. In the second, more complex case, sequential attempts at angioplasty, including the use of three parallel guidewires and their antegrade-retrograde configuration, did not lead to elimination of the residual stenosis. Only the formation of guidewire loops with their transverse orientation in the area of maximum resistance – the “parallel loop technique“ – allowed full balloon expansion, elimination of the hemodynamically significant stenosis, and restoration of access function. The proposed modification redirects mechanical force from an axial to a transverse direction, providing a local effect on the most rigid segment of the stenosis with minimal damage to the unaffected vessel wall. The technique may be considered the method of choice when classical approaches fail. This technique expands the endovascular surgeon's capabilities in preserving vascular access in hemodialysis patients. It is important to emphasize that the proposed approach does not require specialized or expensive equipment. The presented cases confirm that the method allows full expansion of the balloon catheter in situations where standard and classical escalation approaches have proven unsuccessful. This opens additional opportunities for preserving a functioning vascular access in this complex category of patients. Thus, the proposed technique logically complements the existing algorithm for escalation of balloon angioplasty in resistant stenoses of dialysis access and may be recommended for use in clinical practice after confirmation in prospective studies.
No takes yet. Share an insight, caveat, or question.
Шайхутдинов et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: