Key result
Excimer laser angioplasty with balloon dilation achieves ~91% procedural success in restenosed coronary stents.
Why the study?
Balloon angioplasty of in-stent restenosis is limited by a high recurrence rate, and debulking by excimer laser angioplasty is a novel concept requiring evaluation of its safety and efficacy.
Is excimer laser angioplasty with adjunctive balloon angioplasty safe and effective for the treatment of restenosed or occluded coronary stents?
Cohort (n=440)
Yes
Is excimer laser angioplasty with adjunctive balloon angioplasty safe and effective for the treatment of restenosed or occluded coronary stents?
Excimer laser angioplasty with adjunctive balloon angioplasty demonstrated a 91% procedural success rate and acceptable complication rates in treating coronary in-stent restenosis, supporting future randomized evaluation.
Answers are grounded in this paper and cite their sources.
Cohort surveillance supports laser angioplasty feasibility in restenosed stents; leaves open randomized confirmation of benefit.
Objectives This study evaluated safety and efficacy of excimer laser angioplasty for treatment of restenosed or occluded coronary stents. Background Balloon angioplasty of in-stent restenosis is limited by a high recurrence rate. Debulking by laser angioplasty is a novel concept to treat in-stent restenosis. Methods A total of 440 patients with restenoses or occlusions in 527 stents were enrolled for treatment with concentric or eccentric laser catheters and adjunctive balloon angioplasty. Results Laser angioplasty success (< or =50% diameter stenosis after laser treatment or successful passage with a 2.0-mm or 1.7-mm eccentric laser catheter) was achieved in 92% of patients. Adjunctive balloon angioplasty was performed in 99%. Procedural success (laser angioplasty success followed by < or =30% stenosis with or without balloon angioplasty) was 91%. There was neither a significant difference in success with respect to lesion length, nor were there differences between small and large vessels or native vessels and vein grafts. Success was higher and residual stenosis lower using large or eccentric catheters. Serious adverse events included death (1.6%, not directly laser catheter related), Q-wave myocardial infarction (0.5%), non-Q-wave infarction (2.7%), cardiac tamponade (0.5%) and stent damage (0.5%). Perforations after laser treatment occurred in 0.9% of patients and after balloon angioplasty in 0.2%. Dissections were visible in 4.8% of patients after laser treatment and in 9.3% after balloon angioplasty. Reinterventions during hospitalization were necessary in 0.9% of patients; bypass surgery was performed in 0.2%. Conclusions Excimer laser angioplasty with adjunctive balloon angioplasty is a safe and efficient technology to treat in-stent restenoses. These data justify a randomized comparison with balloon angioplasty.
No takes yet. Share an insight, caveat, or question.
Köster et al. (1999) conducted a cohort in Restenosed or occluded coronary stents (n=440). Excimer laser angioplasty (concentric or eccentric catheters) with adjunctive balloon angioplasty was evaluated on Procedural success (laser angioplasty success followed by <=30% stenosis with or without balloon angioplasty). Excimer laser angioplasty with adjunctive balloon angioplasty achieved 91% procedural success and 92% laser success in patients with restenosed or occluded coronary stents.
Synapse has enriched 10 related papers. Consider them for comparative context: