Key result
Renal artery orientation and partial ostial coverage alter local hemodynamics while maintaining left renal flow fraction.
Why the study?
Partial renal ostial coverage by stent-graft fabric during EVAR may alter local flow, motivating this examination of the effects of renal artery orientation and ostial coverage on renal hemodynamics.
Does partial renal ostial coverage and renal artery orientation alter renal hemodynamics and left renal flow fraction after endovascular aneurysm repair in a computational fluid dynamics model?
Does partial renal ostial coverage and renal artery orientation alter renal hemodynamics and left renal flow fraction after endovascular aneurysm repair in a computational fluid dynamics model?
This 4D flow MRI-informed computational study demonstrates that while partial renal ostial coverage (up to 50%) and varying renal artery orientations after EVAR alter near-ostial local flow and wall shear patterns, the overall predicted left renal flow fraction remains within a narrow range (16.759% to 17.212%).
Answers are grounded in this paper and cite their sources.
Bulk renal perfusion appears preserved despite geometric variations; leaves open the clinical relevance of altered local hemodynamics post-EVAR.
Background/Objectives: Partial renal ostial coverage by stent-graft fabric during endovascular aneurysm repair (EVAR) may alter local flow. This study used four-dimensional flow magnetic resonance imaging (4D flow MRI) and computational fluid dynamics (CFD) to examine the effects of renal artery orientation and ostial coverage on renal hemodynamics. Methods: Nine virtual models were constructed from preoperative computed tomography angiography of one patient with an abdominal aortic aneurysm. Left renal artery orientations of 30° upward, horizontal, and 30° downward were combined with nominal linear coverage of 0%, 30%, or 50%. Pulsatile CFD incorporated an MRI-derived inlet waveform, rigid walls, a Carreau viscosity model, and prescribed three-element Windkessel outlet conditions with identical parameters across geometries. CFD results for the horizontal reference model without ostial coverage were compared qualitatively with preoperative 4D flow MRI measurements. Left renal flow fraction was the ratio of cycle-integrated renal outflow to cycle-integrated aortic inflow. Recirculation and wall shear stress-related indices were assessed. Results: The predicted left renal flow fraction ranged from 16.759% to 17.212% across the nine configurations. Local flow and wall shear patterns differed among configurations. In the uncovered horizontal reference model, the MRI and CFD maps showed broadly similar locations of the main high-velocity regions at the selected systolic phase, with local differences during deceleration. This comparison was qualitative. Conclusions: The case illustrates that differences in near-ostial flow patterns can coexist with a narrow range of predicted left renal flow fractions under the prescribed conditions. These exploratory findings require further numerical verification and assessment in additional patient anatomies.
No takes yet. Share an insight, caveat, or question.
Duan et al. (2026) studied Abdominal aortic aneurysm (n=1). Renal artery orientations (30° upward, horizontal, 30° downward) and partial ostial coverage (0%, 30%, 50%) vs. Uncovered horizontal reference model (0% ostial coverage) and preoperative 4D flow MRI was evaluated on Left renal flow fraction (ratio of cycle-integrated renal outflow to cycle-integrated aortic inflow). Varying renal artery orientations and partial ostial coverage altered local flow patterns while maintaining a narrow predicted left renal flow fraction range.
Synapse has enriched 10 related papers. Consider them for comparative context: