Answers are grounded in this paper and cite their sources.
Existing non-destructive testing methods are inadequate for quantifying pre-removal segregation, meaning early defects often go undetected during the critical window for corrective intervention. Motivated by the heat distribution characteristics of segregation layers during concrete hydration, this study proposes a non-destructive infrared thermography method for pre-stripping segregation assessment. Real-time thermal imaging is employed to capture surface temperature distributions on the formwork. From these distributions, a temperature‑rate symmetry index is derived to evaluate the occurrence of segregation, and a temperature‑change‑rate gradient method is proposed to predict the depth of segregation. To further validate the assessment method, Monte-Carlo finite-element simulations, which embed randomly distributed aggregates and mortar phases, are used to reconstruct internal segregation morphologies of concrete. The predicted segregation depths of the proposed method and simulations are both in close agreement with experimental measurements, yielding a depth error between 0.06 cm to 0.58 cm and confirming the reliability of the method during the hydration heat phase. By inversely inferring segregation depth from surface temperature data, this approach enables quantitative, non-destructive assessment before formwork removal, facilitating timely remediation and contributing to the long‑term performance and safety of concrete structures.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.