Answers are grounded in this paper and cite their sources.
Quantitative computed tomography (CT) allows emphysema assessment in chronic obstructive pulmonary disease (COPD), but density-based measurements are sensitive to image reconstruction. We compared deep-learning texture-based quantitative CT (tQCT) with density-based CT (dQCT) for agreement and associations with clinical measures. In this retrospective single-center study, 97 patients with COPD underwent chest CT and pulmonary function testing. Density-based quantification used 1 mm lung-kernel (dQCT1L) and 3 mm soft-tissue-kernel (dQCT3S) reconstructions. Agreement was evaluated using paired comparisons, Bland–Altman analysis, and regression. Mean emphysema extent was 10.3 ± 14.6% with tQCT, 29.7 ± 8.5% with dQCT1L, and 10.8 ± 10.0% with dQCT3S. tQCT correlated with dQCT1L (r = 0.49) and dQCT3S (r = 0.69; both p < 0.01). Mean differences (tQCT minus dQCT1L and dQCT3S) were −19.99 and −0.37 percentage points, respectively, with wide limits of agreement (−44.05 to 4.07 and −18.98 to 18.23) and significant nonlinear magnitude-dependent bias (both p < 0.001). All three measures were inversely associated with corrected diffusing capacity for carbon monoxide (DLCOc), most strongly for tQCT (ρ = −0.522) and dQCT3S (ρ = −0.490). Although dQCT3S showed closer average agreement with tQCT, substantial individual variability precluded interchangeability.
No takes yet. Share an insight, caveat, or question.
Lungenschmid et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: