Whether high-voltage electrostatic field (HVEF) pretreatment improves the performance of thermally modified poplar beyond heat treatment alone remains unclear. This study compared untreated Populus × euramericana (CK), heat-treated wood (HP), and wood pretreated with HVEF before the same heat treatment (HHP) to assess the additional benefits of the sequential treatment. HVEF pretreatment was applied at 60 kV for 6 h, followed by heating at 180°C for 1.5 h under nitrogen. Relative to HP, HHP showed 43.47% lower volumetric water-saturated swelling and 33.26% lower water absorption after 48 h. HHP also had darker surfaces, lower gloss and higher dynamic water contact angles. After 12 weeks of exposure, decay-resistance classifications improved from class III to class II for Trametes versicolor and from class II to class I for Gloeophyllum trabeum. Qualitative Fourier transform infrared spectra indicated treatment-related spectral changes without establishing their chemical mechanisms. Exploratory direct-flame screening recorded shorter afterflame duration and higher residual mass for HHP, but did not establish standard fire performance. HVEF pretreatment therefore provided additional moisture-related and decay-resistance benefits within the tested sequence. These findings provide an experimental basis for designing physical pretreatment strategies to enhance the dimensional stability and biological durability of fast-growing poplar.