Answers are grounded in this paper and cite their sources.
OBJECTIVE: The study aims to assess radiation doses in children undergoing computed tomography scans, establish local diagnostic reference levels, and estimate effective dose and related cancer risk from pediatric head computed tomography examinations. METHODS: 378 pediatric computed tomography examinations were reviewed as part of a retrospective study conducted in a Moroccan hospital. RESULTS: According to the results, the mean total dose-length product values (mGy cm) were 800, 1,125.78, 1,369.5, and 1,218.1 for the age groups <1 year, 1 ≤ 5 years, 5 ≤ 10 years, and 10-17 years, respectively. The mean effective dose values were 8.8 mSv, 7.54 mSv, 5.48 mSv, and 3.9 mSv for the same age groups. Furthermore, the mean cancer risk values were 48.4, 41.47, 30.14, and 21.45 cases per 105 pediatric head computed tomography procedures across the respective age groups. CONCLUSION: The findings of our study highlight the need to further improve professional practices, to revise pediatric computed tomography protocols, and to promote stronger justification prior to any computed tomography examination in these particularly vulnerable age groups.
No takes yet. Share an insight, caveat, or question.
Housni et al. (2026) studied this question.