Key result
Catheter balloon occlusion of reverse Potts shunt enables safe ASD closure in severe pulmonary hypertension.
Why the study?
ASD closure in a patient with a functioning reverse Potts shunt for PH may reduce global hypoxemia without sacrificing right ventricular pressure unloading, but intracardiac operation after reverse Potts shunt had not previously been reported to guide operative decision-making.
Case Report (n=1)
Catheter-based balloon occlusion of a reverse Potts shunt can safely facilitate cardiopulmonary bypass for intracardiac defect repair in patients with severe pulmonary hypertension.
Answers are grounded in this paper and cite their sources.
May facilitate ASD closure in select PH cases with reverse Potts shunt; leaves open need for prospective validation before wider adoption.
BACKGROUND: Atrial septal defect (ASD) closure in the presence of a functioning reverse Potts shunt (rPS) for pulmonary hypertension (PH) may reduce global hypoxemia without sacrificing right ventricular pressure unloading. However, intracardiac operation after rPS has not previously been reported to guide operative decision-making in this scenario. CASE SUMMARY: A 13-year-old girl with a history of rPS for PH presented for ASD closure because of hypoxia and exercise intolerance. To safely close the ASD on cardiopulmonary bypass, the rPS was occluded with a catheter-based balloon. DISCUSSION: Coexisting ASD and rPS in a patient with severe PH presents a complex hemodynamic scenario. Furthermore, intracardiac operation in the setting of patent rPS and PH presents certain technical challenges. Multidisciplinary care is necessary for safe and effective management of coexisting ASD and rPS. TAKE-HOME MESSAGE: Balloon occlusion of reverse Potts shunt can be safely performed in select patients to expand feasibility for repair of intracardiac defects in PH.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2026) conducted a case report in Atrial septal defect with severe pulmonary hypertension and prior reverse Potts shunt (n=1). Catheter-based balloon occlusion of reverse Potts shunt during atrial septal defect closure on cardiopulmonary bypass was evaluated on Feasibility and safety of atrial septal defect closure on cardiopulmonary bypass. Catheter-based balloon occlusion of a reverse Potts shunt enabled safe atrial septal defect closure on cardiopulmonary bypass in a 13-year-old girl with severe pulmonary hypertension.