Key result
Percutaneous PFO closure resolves refractory hypoxemia and enables ventilator weaning after type A dissection repair.
Why the study?
Pulmonary function can be reduced after surgery for acute type A aortic dissection due to several possible causes, making it necessary to identify the main underlying cause.
Case Report (n=1)
No
Occult patent foramen ovale should be suspected in unexplained postsurgical hypoxemia after acute type A aortic dissection repair, as prompt percutaneous closure can rapidly reverse hypoxia and enable ventilator weaning.
Answers are grounded in this paper and cite their sources.
May warrant PFO evaluation in refractory post-dissection hypoxemia; leaves open prospective validation before broader adoption.
BACKGROUND: After surgery for acute type A aortic dissection, pulmonary function can be reduced because of several possible causes. It is necessary to identify the main cause. CASE SUMMARY: A patient experienced refractory hypoxemia following type A aortic dissection repair. Despite proper respiratory and inotropic support, and near-normal chest imaging, severe hypoxia persisted. Echocardiography revealed an occult patent foramen ovale (PFO) with significant right-to-left shunting, driven by positive-pressure mechanical ventilation and elevated right-sided cardiac pressures. Percutaneous transcatheter closure immediately improved oxygenation, enabling successful ventilator weaning. DISCUSSION: Occult PFO should be suspected in unexplained postsurgical hypoxemia. Early echocardiographic evaluation and prompt percutaneous closure can rapidly reverse hypoxia, preventing prolonged mechanical ventilation and secondary complications. TAKE-HOME MESSAGES: Persistent refractory hypoxemia after acute type A aortic dissection repair is not always pulmonary in origin. Occult PFO should be suspected and early echocardiographic confirmation with prompt PFO closure can produce immediate clinical improvement.
No takes yet. Share an insight, caveat, or question.
Chaubey et al. (2026) conducted a case report in Severe refractory hypoxemia caused by occult patent foramen ovale after acute type A aortic dissection repair (n=1). Percutaneous transcatheter patent foramen ovale closure was evaluated on Resolution of refractory hypoxemia and successful ventilator weaning. Percutaneous transcatheter closure of an occult patent foramen ovale immediately resolved refractory hypoxemia and enabled ventilator weaning in 1 patient after acute type A aortic dissection repair.
Synapse has enriched 10 related papers. Consider them for comparative context: