Answers are grounded in this paper and cite their sources.
An experimental study was conducted to evaluate the effects of adiabatic length, filling ratio, heat inputs, working fluids, and circulation mode on the thermal performance and flow stability characteristics of closed-loop thermosyphon (CLT) and pump-driven loop thermosyphon (PDLT) systems. Experiments were conducted for adiabatic lengths in the range of 200–800 mm, filling ratios in the range of 0.3–0.7 and up to 2000 W heat input at two-phase operating conditions. The results showed that thermal resistance decreased from about 0.12 K/W to 0.05 K/W by increasing the heat input due to enhanced nucleate boiling and vapor-liquid circulation. The minimum thermal resistance and stable operation were obtained with a filling ratio of about 0.6 for both CLT and PDLT systems. The increase of the adiabatic length from 200 mm to 800 mm resulted in a 40–60% increase of the thermal resistance, caused by the increase of the frictional pressure drop and the decrease of the circulation effectiveness in the loop. The PDLT configuration showed better thermal performance, reducing the thermal resistance by about 35–50% compared to the natural circulation system. High heat inputs and longer adiabatic lengths were mostly associated with flow instability phenomena such as oscillatory flow, geyser boiling and intermittent dry-out. Generalized empirical and dimensionless correlations predictive of these results were developed and validated using experimental data, including the Reynolds number, Bond number and geometrical parameters. The proposed correlations could predict the thermal resistance with coefficient of determination values bigger than R 2 > 0.981 in ± 20% deviation. Operational stability maps have been constructed to identify stable and unstable operation zones. The novelty of this study lies in the systematic integration of experimental thermal-performance data with comparative data-driven prediction models to evaluate the influence of heat input, filling ratio, and adiabatic length on the thermal resistance of closed-loop thermosyphons. Unlike studies focusing on individual operating parameters or isolated prediction techniques, the present work provides a comparative assessment of multiple prediction approaches using a common experimental dataset. The results establish the predictive capabilities and limitations of these models and identify operating-condition-dependent trends in thermal performance.
No takes yet. Share an insight, caveat, or question.
Birajdar et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: