Answers are grounded in this paper and cite their sources.
Recent studies have highlighted the effectiveness of semi-active control strategies in optimizing the energy components of the seismic response of plan-asymmetric structures. However, this effectiveness is generally demonstrated through response quantities averaged over broad record sets, which obscures its dependence on site conditions and on the frequency and impulsive content of the excitation. This study presents a closed-form, energy-driven control framework for viscoelastic semi-active devices in one-way asymmetric systems and performs a disaggregated parametric analysis of the elastic- and kinetic-energy minimization algorithms. Using 85 far-field and near-fault records, seismic performance is examined as a function of translational period and structural eccentricity, and then broken down by EC8 soil class and record character. In addition to conventional peak and mean measures, the median reduction, its interquartile dispersion and coefficient of variation are introduced, together with correlations between energy reduction and signal indicators, namely the PGA/PGV ratio and the specific energy density. The kinetic-energy algorithm proves strongly governed by the frequency content of the excitation, whereas the elastic-energy algorithm is uncorrelated with either indicator; both algorithms are less effective on soft-soil and near-fault records. The results are organized into algorithm-selection maps supporting design choices for a given site and expected demand.
No takes yet. Share an insight, caveat, or question.
Iuliis et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: