Answers are grounded in this paper and cite their sources.
BACKGROUND: Reliable quantification of vitamins A and E in animal tissues is important for veterinary diagnostics, toxicological investigations, nutritional assessment, and food analysis. Existing tissue-based methods are challenged by complex lipid-rich matrices, analyte instability, and inherent difficulties associated with validating endogenous compounds. OBJECTIVE: The objective was to develop and validate a robust LC-MS/MS method for simultaneous determination of retinol (vitamin A) and α-tocopherol (vitamin E) in liver tissue and evaluate complementary approaches for assessing method performance with endogenous analytes. METHOD: Liver samples (50 mg) were subjected to high-energy bead homogenization, controlled alkaline saponification, and supported liquid extraction using hexane. Quantitation was performed by LC-MS/MS with isotope-dilution calibration. Method performance was evaluated using ICH M10 validation principles. Additional studies included parallelism testing, standard-addition analysis, and exhaustive extraction experiments to assess performance for endogenous analytes. RESULTS: Calibration models met predefined acceptance criteria across the validated range. Parallelism evaluation showed no significant differences between calibration-curve and tissue-dilution slopes, supporting the use of solvent-based external calibration for liver tissue analysis. Standard-addition experiments showed agreement between endogenous concentrations estimated by standard addition and those obtained using external calibration. Recovery and precision were acceptable for both analytes and improved following pre-homogenization of tissue. Exhaustive extraction experiments showed no meaningful increase in measured vitamin responses following a secondary extraction under the conditions evaluated. CONCLUSIONS: A robust LC-MS/MS method was developed for simultaneous determination of retinol and α-tocopherol in liver tissue using rapid saponification and supported liquid extraction. In addition to demonstrating analytical performance suitable for veterinary diagnostic applications, this study provides additional evidence supporting the utility of parallelism and standard-addition studies during endogenous-analyte validation and explores exhaustive extraction as a complementary approach for evaluating extraction completeness of incurred analytes. HIGHLIGHTS: Parallelism, standard-addition, and exhaustive-extraction studies provided complementary evidence supporting method performance for endogenous vitamins in liver tissue.
No takes yet. Share an insight, caveat, or question.
Rice et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: