Answers are grounded in this paper and cite their sources.
Introduction High renewable penetration couples forecast errors, storage dynamics, and grid constraints. We study a knowledge-guided supervisory architecture that maps operational context to bounded uncertainty margins, carbon and peak weights, degradation multipliers, and reserve targets. Methods A worst-corner rolling linear program coordinates battery, hydrogen, and thermal storage, followed by deterministic realized-balance repair. A large language model (LLM)-compatible interface is proposed, but the experiments use deterministic numeric context rules and do not execute retrieval, language-model inference, or a text parser. The synthetic 7-day comparison gives all model predictive control (MPC) controllers the same issued grid-event notices and emergency recourse. Results Each MPC controller achieves numerical zero unserved energy. Relative to fixed robust MPC, the adaptive supervisor decreases nominal peak import from 439.86 to 414.81 kW but increases evaluation cost from 3,160.73 to 3,337.12 USD and service-normalized emissions from 145.28 to 148.01 kg CO 2 /MWh. Four additional randomized scenarios show the same mean cost-peak trade-off, without establishing universal superiority. Isolated ablations and notice-recourse controls show that zero shortage is not unique to adaptive reasoning. All 57 released trajectories pass physical and accounting checks. Discussion Exact-projection and recursive-feasibility statements remain conditional theoretical results, not certificates for the implemented heuristic.
No takes yet. Share an insight, caveat, or question.
Ding et al. (2026) studied this question.