Answers are grounded in this paper and cite their sources.
Photovoltaic (PV) and hybrid photovoltaic/thermal (PVT) systems are competitive clean-generation technologies, but their experimental assessment requires the reliable, simultaneous measurement of electrical, thermal, and environmental quantities. The main contribution of this work is a microcontroller-based data acquisition system, with redundant local storage and cloud transmission, installed in an experimental plant with two PV and two PVT modules. Extending previous results, the system is evaluated over 22 days of continuous operation (30,297 samples), achieving 99.1% completeness and only 0.02% of spurious samples. To demonstrate its capabilities, the collected data are used to validate a temperature-corrected electrical model, with a daily-energy error between 4.7% and 7.6%, to thermally characterize the PVT collector from a forced-circulation test, and to propagate measurement uncertainties to the efficiencies. The collector model, fed with real measured series, then simulates forced circulation over the 18 thermosiphon days, estimating a potential gain of 96% (79% net), an upper bound that depends on hot-water consumption. A control simulation shows that the operating strategy is decisive: kept continuously on, the pump saturates the reservoir and wastes pumping, whereas judicious actuation preserves the gain. The validated model and the open dataset support embedded, model-based monitoring and control of the plant.
No takes yet. Share an insight, caveat, or question.
Coutinho et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: