Answers are grounded in this paper and cite their sources.
To address the problem that bonding failure in the bridge arms of strain-gauge full bridges used in advanced equipment is highly concealed and difficult to identify online through conventional calibration or manual inspection, this paper proposes an online built-in test (BIT) diagnosis method based on local self-heating excitation by establishing a local self-heating thermal network model for the bridge arm. The proposed method enables addressed detection of bridge-arm bonding faults, with the arm location supplied by the selected excitation channel. Meanwhile, a model-based criterion for the minimum resolvable excitation duration and a healthy-reference fault-decision framework are formulated; normalized cooling-recovery curves are used for qualitative comparison. The results demonstrate the feasibility of using the self-heating response for bonding-fault manifestation and channel-addressed fault detection in the tested cases; statistical diagnostic performance will be assessed in future work.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.