Answers are grounded in this paper and cite their sources.
Driven by global net-zero goals, the integrated electricity–hydrogen–ammonia system provides a pathway for coordinating renewable energy utilization with green chemical production. To address dynamic mismatch and control heterogeneity between electrical and chemical units, this paper presents a coupled multi-energy model and a multi-timescale scheduling strategy. First, nonlinear electrolyzer conversion, part-load ammonia auxiliary consumption and equipment degradation costs are incorporated into the hydrogen–electricity hybrid storage model. Then, a two-stage optimization architecture is designed: day-ahead mixed-integer programming for unit commitment, and intra-day CNN-LSTM dynamic rolling optimization. Finally, grid-connected and off-grid tests using normalized public load and photovoltaic profiles examine the coordinated operation of the system. Results show that all four grid-connected cases meet the daily ammonia delivery requirement of 200 kg, with operating margins ranging from −491.84 to 859.68 CNY/day. The three four-hour off-grid cases maintain ammonia production without load shedding under the tested conditions. These findings provide an operational reference for integrating renewable energy with green ammonia synthesis.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: