This study introduces a novel triple-phase energy dissipation concept integrating shear thickening fluid (STF) impregnated and polyurethane (PU) foam filled auxetic thermoplastic polyurethane (TPU) structures for superior impact resistance under low-velocity impact (LVI) loading. Three auxetic geometries – reentrant (RE), arrowhead (AH), and starshaped (SS) – were manufactured via fused deposition modeling (FDM) and subjected to a hybrid reinforcement strategy. PU foams were synthesized using a full factorial design, and STF was prepared with 20 wt.% fumed silica dispersed in polyethylene glycol. LVI tests were conducted at 15–270 J using a drop-weight apparatus. The arrowhead geometry achieved the highest specific energy absorption of 32.8 J g −1 at 180 J, with peak force increasing by 18.3 %–8,400 N over the neat structure. The hybrid filling reduced maximum displacement across all geometries, limiting deformation to 70 mm compared to 100 mm for unfilled reentrant structures at 180 J, and preventing bottoming-out at 270 J. The most pronounced synergy was observed in the reentrant configuration, where STF–PU filling surpassed the peak force of PU alone, while PU filling independently maximized load-bearing capacity in the starshaped geometry. These findings establish a design framework for next-generation protective systems in ballistic panels, helmets, and impact-critical applications.