Why the study?
Multi-mechanistic CIED-related massive TR with a large coaptation gap and prior anticoagulation-related bleeding can be poorly suited to isolated TEER or transcatheter tricuspid valve replacement.
Population
89-year-old male with a CIED and symptomatic massive tricuspid regurgitation
Design
Case report
Answers are grounded in this paper and cite their sources.
Demonstrates successful sequential annuloplasty and edge-to-edge repair in pacemaker-induced tricuspid regurgitation, highlighting an anatomy-guided approach preserving functional leads.
A 89-year-old male with a cardiac implantable electronic device (CIED) presented with symptomatic massive tricuspid regurgitation (TR). Previous major anticoagulation-related gastrointestinal bleeding made transcatheter tricuspid valve replacement unfavourable. Transoesophageal echocardiography demonstrated marked annular dilatation (mean diameter 42.3 mm), leaflet tethering and a 13-mm anteroseptal coaptation gap (Panel A). The pacing lead coursed near the posteroseptal commissure and impinged on the septal leaflet, contributing to a broad, multijetic regurgitation (Panel A). Rather than lead extraction or attempting edge-to-edge repair across the large coaptation defect, K-Clip annuloplasty was performed to modify the annular substrate around the lead. Annular remodelling reduced the septolateral diameter to 32.2 mm and the anteroseptal coaptation gap to 2 mm, improved leaflet coaptation and reduced TR from massive to moderate (Panel B). Importantly, remodelling reshaped the lead–septal leaflet interaction and transformed the broad regurgitant defect into a predominantly localized anteroseptal jet. This newly defined target enabled subsequent TriClip G5 implantation, further reducing TR to mild without lead extraction or repositioning (Panel C). The total device insertion-to-removal time was assessed as 75 min. This case highlights a staged, anatomy-guided strategy in which annuloplasty served as anatomical preconditioning, transforming unfavourable anatomy into a target amenable to transcatheter edge-to-edge repair (TEER) while preserving the functional transvalvular lead.1–3 More broadly, this sequential substrate remodelling followed by targeted repair may also provide a treatment framework for selected multi-mechanistic TR poorly suited to isolated TEER beyond CIED-related disease. Its procedural and long-term value warrants further prospective evaluation. Supplementary data are not available at European Heart Journal online. Authors have no conflicts of interest to disclose. No data were generated or analysed for or in support of this paper. This study was funded by National Natural Science Foundation of China (82470377, 8240021011).
No takes yet. Share an insight, caveat, or question.
金沁纯 et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: