Key result
Low and oscillating shear stress is inversely associated with neointimal hyperplasia near stent step-ups.
Why the study?
The mechanism of in-stent restenosis has not been fully elucidated, and clinical evidence regarding the localizing role of oscillating shear stress in in-stent restenosis was lacking.
Case Report (n=1)
No
Answers are grounded in this paper and cite their sources.
Shows focal in-stent restenosis aligning with low oscillating shear stress near a lumen step-up in a stented artery, suggesting flow separation drives neointimal growth.
Roles of Low and Oscillating Shear
No takes yet. Share an insight, caveat, or question.
Thury et al. (2002) conducted a case report in Focal in-stent restenosis of the left anterior descending coronary artery (n=1). Low and oscillating wall shear stress at stent step-up region was evaluated on In-stent average neointimal thickness (neointimal hyperplasia) per cross section (r2 = 0.34, p=<0.01). Low and oscillating shear stress near a proximal stent step-up showed a non-linear inverse relationship with neointimal hyperplasia at 4 months.