Mathematical modeling suggests that the effect of time-dependent blood flow on atherogenesis may be driven by the distribution of mean wall shear stress rather than its time-varying components.
Answers are grounded in this paper and cite their sources.
Should not change clinical shear stress assessment in atherosclerosis; hypothesis-generating for mean distribution over oscillatory components in atherogenesis models.
The site opposite an end-to-side anastomosis, resulting from femoral bypass surgery, and the carotid sinus are two regions well known to be prone to fibrous intimal hyperplasia or atherogenesis, respectively. The blood flow at these two sites features a stagnation point, which oscillates in strength and position. Mathematical models are used to determine some of the features of such a flow; in particular, the mean wall shear stress is calculated. The positional oscillations cause a significant change in the distribution and magnitude of the mean wall shear stress from that of the well-studied case of a stagnation point that oscillates only in strength. It is therefore proposed that the recorded effect of time dependence in the flow upon atherogenesis could still be a result of the distribution of the mean and not the time-varying components of the wall shear stress.
No takes yet. Share an insight, caveat, or question.
Hazel et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: