Answers are grounded in this paper and cite their sources.
Background: Electronic portal imaging devices (EPIDs) are widely used for transit dosimetry in administering radiotherapy. However, no dedicated methods for determining the tolerance limit of EPID-based in vivo dosimetry (EIVD) in clinical practice have been reported. The objective of this study was to determine the clinical EIVD tolerances for lung cancer radiotherapy through the application of the statistical process control (SPC) method. Methods: A total of 1,473 fractional two-dimensional EIVD gamma pass rates (GPRs) from 163 patients with lung cancer were analyzed. Patients were placed into Group A (109 patients; 2–3 Gy/fraction) or Group B [54 patients; treated with stereotactic body radiation therapy (SBRT), >6 Gy/fraction]. Control charts were generated via scaled weighted variance across two phases. In Phase I, an iterative "identify–check–eliminate–recalculate" procedure was used to exclude clinically unacceptable fractions and establish an in-control tolerance. In Phase II, process stability was validated according to in-control tolerance limits. Image-guided radiation therapy was used to identify root causes for out-of-control fractions. Process capability was evaluated in terms of the Process Capability Index (Cpk). Results: The initial 2D EIVD GPRs were 95.49%±4.66% for Group A and 90.28%±6.07% for Group B. The in-control EIVD GPRs were 96.42%±2.69% for Group A and 92.19%±3.73% for Group B. After the iterative identify–check–eliminate–recalculate procedure was applied, the tolerance limits of Group A increased from an initial 89.22% to 90.90%, and those of Group B increased from 71.79% to 85.78%. Through clinical verification, we categorized the causes of eliminated out-of-control EIVD fractions into three categories: setup errors, anatomical variations, and plan-related errors. In Phase Ⅰ, the proportion of specific causes for out-of-control fractions in Group A was as follows: setup errors, 5.06%; anatomical variations, 1.76%; and plan-related errors, 1.03%. For Group B, these proportions were 2.80%, 11.21%, and 8.41%, respectively. The Cpk of Group A improved from 0.39 to 1.41, and that of Group B improved from 0.29 to 0.64. In Phase Ⅱ, the proportion of specific causes for out-of-control fractions for Group A was as follows: setup errors, 5.41%; anatomical variations, 10.75%; and plan-related errors, 8.36%. For Group B, these proportions were 4.76%, 6.35%, and 12.70%, respectively. Conclusions: This study supports the feasibility of using the SPC method to establish the tolerance limit of 2D EIVDs in patients with lung cancer treated with conventional radiotherapy and SBRT. The results may serve as a preliminary reference for establishing acceptable tolerance limits for EIVD in lung cancer radiotherapy at other centers, yet more accurate institution-specific limits with the proposed methodology should be determined with local data.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: