Answers are grounded in this paper and cite their sources.
Restricting the temperatures of Li-ion electric vehicle batteries within their safe operating limits is necessary in order to preserve their energy storage capacity and lifespan and mitigate safety concerns associated with thermal runaway. This presents a major thermal management challenge, since uneven temperature distribution and localised high-temperature regions in battery cells, often referred to as hotspots, may occur during the battery cycling process, over long journeys or in severe weather conditions. This paper focuses on the optimization of serpentine minichannel cold plates with intersecting V-shaped minichannels (SMCCP-IVSMC), where the goals are to minimise the magnitude and distribution of hotspots within the batteries whilst also minimising hydraulic pumping power consumption. It proposes a novel supervised deep neural network model that combines a fully connected neural network with a transposed convolutional neural network (CNN), within a multi-objective hybrid optimization approach that can account for trade-offs between competing thermal and hydraulic objectives. The optimization methodology integrates surrogate modelling based on CNN and Gaussian Process Regression (GPR) with optimizations using the Generalised Differential Evolution (GDE3) and Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) methods to identify the best compromise solutions among Pareto-optimal options. The use of geometrical design variables as input to parameterise the minichannel dimensions within the cold plates, rather than image-based spatial representations of the channel geometry, enables the CNN to be trained using smaller training CNN datasets than reported previously. The optimizations identify many opportunities to enhance performance. For example, at a hotspot threshold of 35 °C, the Pareto-optimal set provides distinct performance benefits, with one design reducing hotspot size by ~98% when hotspot minimisation is prioritised, and another design reducing pumping power by ~29% when pumping power reduction is prioritised, compared with the current benchmark design. When the hotspot threshold is increased to 38 °C, prioritising pumping power minimisation reduces pumping power consumption by ~65% relative to the benchmark.
No takes yet. Share an insight, caveat, or question.
Mahmood et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: