A zero-dimensional dynamic mass–energy balance model was developed for the balance-of-plant (BOP) system of a proton exchange membrane water electrolyzer (PEMWE). The model treats the whole system, comprising the stack, gas–liquid separation vessels, circulation and makeup water loops, and a counterflow heat exchanger, as interconnected blocks. The electrochemical sub-model computes the cell voltage from the Nernst equation and the activation, ohmic, and concentration overpotentials. Mass balance sub-models account for Faraday's law gas generation, electroosmotic drag, and pressure-driven water transport across the membrane. Thermal balance combines reaction heat generation, water flows, and ambient losses by convection and radiation, while the heat exchanger is described by the effectiveness–number of transfer units (NTU) method. An iterative temperature loop yields a steady-state operating temperature of approximately 80 °C. The cell-level model was compared with measured polarization data, yielding a mean relative error of approximately below 0.2 %. The system model was benchmarked against an experimentally verified 50 kW PEM water electrolyzer plant, confirming that a voltage efficiency of at least 70 % is attainable. Flow-rate sensitivity and dynamic response analyses were further carried out to verify the structural consistency of the system model.