Answers are grounded in this paper and cite their sources.
Connecting alkaline electrolyser stacks in series through a shared electrolyte circuit reduces the plant-level DC current and power-conversion cost, but introduces stray currents that bypass the cells. Suppressing these currents requires longer or narrower external connections, which increase the electrolyte pumping demand. Using a cell-resolved equivalent-circuit model with per-substack thermal balances and Darcy–Weisbach pressure-drop modelling, this work maps the trade-off for a 600-cell system over the external port length, port area, manifold length, and partitioning. The total loss falls steeply over the first metres of port length; beyond a diminishing-returns length of 15 m to 26 m, where the total loss lies within 0.06 percentage points of its minimum, further lengthening saves very little. Halving the external port area halves the external stray-current loss but raises the pumping demand about fivefold, so lengthening the ports suppresses stray currents at a lower pumping cost. The port cross-section that minimises the external losses grows with the port length. A sensitivity analysis of load, electrolyte concentration, bends, and pump efficiency shows that an efficient pump and few bends allow longer external ports. Mid-feeding and long external manifolds are favourable, and finer partitioning can reduce the dominant internal stray-current loss to less than a fifth.
No takes yet. Share an insight, caveat, or question.
Anttilainen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: