Answers are grounded in this paper and cite their sources.
This study investigates the bond performance of beams prestressed with sand-coated carbon fibre-reinforced polymer (CFRP) tendons under cyclic loading. Distributed fibre optic sensing (DFOS) was employed to monitor the tendon strain distribution along the beam. Cyclic loading tests were performed for two distinct load cases over a maximum of 10 million cycles. When loads were applied at a shear span-to-beam depth ratio of approximately 5.4, no tendon bond failure in the prestress transfer zone was observed within the investigated load range. When the load was applied near the estimated development length, bond failure occurred and the tendon strains remained well below the ultimate strain associated with static tendon rupture. Based on these findings, a failure criterion was derived that accounts for the effects of cyclic loading, including bond degradation at flexural and shear cracks near the supports. Depending on the specific case, either static tendon rupture, fatigue tendon rupture, or anchorage bond failure may occur. Finally, the five distinct bond failure modes observed during the experiments were analysed via light microscopy and scanning electron microscopy (SEM).
No takes yet. Share an insight, caveat, or question.
Ott et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: