Answers are grounded in this paper and cite their sources.
Working note applying the Bennett (1934) straight-cylinder relation, I_B = π a (8p/μ0)^1/2, to three published arc columns burning in gas at 0.67–1.3 atm. For a laser-guided 80 cm spark in air (30–43 A, 3–4 mm radius) the relation gives about 260, 226 and 234 times the measured current at three capacitor settings; for a 30 A oxygen plasma-cutting arc (0.6–0.7 mm radius) about 58 times; for a 55 A carbon arc used to grow nanotubes (0.2 cm core radius, helium/hydrogen at 67 kPa) about 75 times. Edge magnetic pressure is about 2, 34 and 12 Pa respectively against 67,000–130,000 Pa of surrounding gas. With the welding arc of the companion note (ratio 32 at 1 atm), these are four measured columns in which surrounding gas pressure carries the pressure balance. Companion to doi:10.5281/zenodo.24492736 and doi:10.5281/zenodo.24380018. Statements concern the listed measurements only.
No takes yet. Share an insight, caveat, or question.
Kirk Bagger (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: