Answers are grounded in this paper and cite their sources.
This working note applies the Bennett (1934) pinch relation, as used in the Kirk Axial Pinch Theory, to three more published laboratory measurements of glowing gas columns. The formula gives the current a straight column would need for its own magnetic squeeze to hold back the gas pressure in it. For a single barrier-discharge filament in open air (Vanraes et al. 2018), the measured current is about 3,630 times smaller than that. For a low-pressure argon–mercury lamp column (Bakker & Kroesen 2000), it is about 5,140 times smaller at the fill pressure, and at least 55 times smaller on electron pressure alone. For a 1.8 kA air arc in a laboratory breaker model (Becerra et al. 2019), it is at least 2.9–4.2 times smaller, a lower bound. All pressures, ranges and caveats are stated plainly.
No takes yet. Share an insight, caveat, or question.
Kirk Bagger (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: