Answers are grounded in this paper and cite their sources.
Background/Objectives: Accuracies approaching 100% have been reported for fundus disease classification on the ODIR-5K dataset, including 98.2% in our unpublished preliminary pipeline. We quantified how labelling and evaluation shape such figures. Methods: Each image was classified as normal or as one of seven disease categories using eye-level labels from ophthalmologists’ per-eye keywords (5990 images, 3263 patients). Four convolutional neural networks were fine-tuned, tested externally on RFMiD and locally recalibrated. Results: With eye-level labels and patient-level splits, the reference model (EfficientNetB0, 384 pixels) reached a test macro-F1 of 0.659 (95% CI 0.609–0.702) and an accuracy of 70.8% (67.3–74.0%). The preliminary pipeline was trained and evaluated on the same images; its reproduction reached a macro-F1 of 1.000 and 100% accuracy on training images but 0.499 and 53.2% on held-out images. Propagating patient labels to eyes altered 16.4% of labels, and adding fellow eyes to training raised macro-F1 by 0.032 (95% CI −0.004 to 0.068). On four categories shared with RFMiD, macro-F1 and accuracy were 0.815 and 74.9% internally and 0.663 and 75.3% externally. Recalibration raised RFMiD macro-F1 from 0.657 to 0.735 but lowered diabetic retinopathy sensitivity from 0.925 to 0.775. Conclusions: Near-perfect accuracy came from evaluation on training images; fellow-eye leakage inflated performance far less.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: