Accurate detection of minute strains in materials is essential for assessing mechanical properties, microstructural stability and service lifetime. In synchrotron radiation X-ray diffraction residual stress analysis, conventional methods typically employ square or circular beam spots. However, for elongated specimens such as thin coatings, line-shaped beam spots enhance signal intensity and measurement efficiency although they introduce a `double periodic distortion' error. This study proposes a novel data fitting method for Debye rings that effectively suppresses the `centroid drift' effect, previously obscured by errors, through dynamic centroid correction (DCC). The method also incorporates successive difference correction (SDC) to eliminate the double periodic distortion caused by line-shaped beam spots. By applying dynamic iterative correction to the diffraction peak centroid and differential processing to sequential measurement data, this approach significantly improves the accuracy of strain fitting to a level of 10 −6. The accompanying automated processing software seamlessly integrates DCC and SDC algorithms, providing a reliable and user-friendly tool for high-precision stress characterization and performance optimization of thin coatings.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.