Answers are grounded in this paper and cite their sources.
The optimal spatial deployment of automated external defibrillators (AEDs) is critical for improving survival from out-of-hospital cardiac arrest. A case study was conducted in Putian City, Fujian Province, China. The accessibility of 375 existing AEDs was evaluated under walking and driving modes, and their placement was optimized using the Gaussian two-step floating catchment area (Ga2SFCA) method, location set covering problem (LSCP), and maximal covering location problem (MCLP). Under the 4-minute walking threshold, only 253,900 people are currently covered, and 92.09% of the population remains unserved, indicating both insufficient quantity and spatial imbalance. Full coverage of coverable demand points under the walking mode required 2,453 additional units. Because the driving mode depends on immediate vehicle availability, the walking mode was adopted as the baseline for optimization. Scenario comparison identified 300 additional units as the preferred near-term option: raising coverage to 35.44%, with nearly 40% allocated to Xianyou County, where the gap is largest. A phased path is proposed accordingly: 300 units in the near term, a cumulative 500 units in the medium term, and continued coverage expansion in the long term. This path can inform emergency medical facility planning in analogous small and medium-sized cities.
No takes yet. Share an insight, caveat, or question.
Xie et al. (2026) studied this question.