Elbow inlet conduits guide flow to the impellers of large low-head pumping stations for water transfer and drainage, where piers may be needed for structural support. Their design is often judged by outlet-flow indices of the isolated conduit, which may not reflect whole-system performance. This study compared four bend profiles and three pier lengths through steady ANSYS CFX simulations coupling the inlet conduit, impeller, volute, and outlet pipe (SST k − ω; Frozen Rotor), so that indices and efficiency came from one model. Predicted head and efficiency were within 5% of model tests. At design flow Qd, Scheme B achieved the highest head, efficiency, axial-velocity uniformity (Vu), and flow angle; its efficiency exceeded Scheme A by 0.571 percentage points (pp). Piers of 1.0D, 1.4D, and 1.8D, evaluated over 0.8–1.2Qd, increased Vu at 0.8Qd, Qd, 1.2Qd but reduced system efficiency by 0.21–0.52 pp at and above Qd. At 0.8Qd, they increased efficiency by 0.64–2.42 pp; the 1.4D pier achieved the highest efficiency, whereas the 1.8D pier achieved the highest Vu. At Qd, most of this penalty arose on the pump side, mainly as additional impeller loss. Pier selection should therefore consider structural requirements, operating range, and whole-system efficiency.