Answers are grounded in this paper and cite their sources.
Background/Objectives: Automatic cephalometric analysis may reduce processing time in orthodontic practice, but its clinical reliability depends on the agreement of derived measurements with expert assessment. This study aimed to evaluate the agreement between automatic cephalometric analysis and manual digital tracing performed by an orthodontic specialist for continuous cephalometric measurements and sagittal skeletal classification using AudaxCEPH Cephalometric software. Methods: In this retrospective comparative study, 97 lateral cephalometric radiographs were analyzed using manual digital tracing by a specialist in orthodontics and dentofacial orthopaedics and automatic tracing with AudaxCEPH Version 2.0. Skeletal, dental, and soft-tissue parameters derived from the Segner–Hasund and LBD analyses were compared using paired statistical tests and agreement analyses for continuous and categorical outcomes. Sagittal skeletal classification was based on prespecified ANB thresholds (Class III, <0°; Class I, 0–4°; Class II, >4°), applied identically to both tracing approaches, and classification concordance was assessed using Cohen’s κ. Results: Sagittal skeletal classification was concordant in 93 of 97 examinations (95.88%; 95% CI, 89.87–98.38%), with an unweighted Cohen’s κ of 0.927 (95% CI, 0.858–0.997) and a linearly weighted κ of 0.936 (95% CI, 0.876–0.997). Agreement for continuous measurements varied across cephalometric parameters. ANB showed a mean bias of +0.31° (95% limits of agreement [LoA], −1.16° to +1.77°), whereas NL/ML exhibited a mean bias of −0.92° with substantially wider LoA (−5.29° to +3.45°). For NL/ML, 40 of 97 examinations (41.24%) exceeded the exploratory 2° difference threshold. Among parameters without identical exported measurements, ICCs ranged from 0.92 to 0.997; OcP/TVL and −1/OcP yielded identical recorded outputs (ICC = 1.00), although independence of the underlying geometric constructions could not be confirmed. Automatic tracing required approximately 20 s compared with 4–7 min for manual digital tracing. Conclusions: AudaxCEPH automatic tracing substantially reduced initial analysis time and demonstrated high overall concordance with expert-performed manual digital tracing. However, agreement was parameter-dependent, with substantial individual-level disagreement for selected measurements, particularly NL/ML. These findings support clinician verification of diagnostically relevant measurements and caution against assuming interchangeability solely on the basis of high ICC values.
No takes yet. Share an insight, caveat, or question.
Mihăilescu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: