Answers are grounded in this paper and cite their sources.
Background: Recurrent demineralization at restoration margins threatens the longevity of Class I restorations, and restorative materials marketed as ion-releasing or “bioactive” are proposed to modify the mineral status of the adjacent tooth tissue. Objective: Our objective was to compare the calcium-to-phosphorus (Ca/P) weight ratio of demineralized enamel and dentin adjacent to three ion-releasing restorative systems and one conventional bulk-fill composite after six months of storage in artificial saliva, using energy-dispersive X-ray spectroscopy (EDX), and to describe the tooth–restoration interface by scanning electron microscopy (SEM). Methods: Standardized Class I cavities (3 mm × 3 mm × 2 mm) were prepared in 40 sound human molars, which were randomly allocated to four groups (n = 10): Beautifil-Bulk, Predicta® Bioactive Bulk, Stela self-cure composite, and Tetric® N-Power Fill 2 (reference comparator). Each tooth was sectioned from a region close to the prepared cavity to obtain two ≈2 mm slices: one served as the sound baseline reference, and the other one was obtained after tooth demineralization (acetic acid, pH 4.5, 7 days), analyzed by EDX, restored, and stored for six months in artificial saliva containing calcium and phosphate, and each specimen was re-sectioned for EDX (Ca/P at 50 µm from the interface) and SEM (interfacial gap width). Between-group differences at each stage and in per-tooth change scores were analyzed with Welch’s ANOVA and Games–Howell tests, and within-tooth changes were analyzed from the linked per-tooth measurements with paired tests (Holm-adjusted); gap widths were measured on representative micrographs and reported descriptively. Results: Ca/P ratios did not differ among groups at baseline (enamel p = 0.195; dentin p = 0.915) or after demineralization (p = 0.472 and p = 0.773). After storage, enamel Ca/P differed among groups (p < 0.001); recovery from the demineralized state was greater adjacent to Predicta® (+0.57 ± 0.18) than adjacent to Stela (+0.24 ± 0.08), Beautifil-Bulk (+0.11 ± 0.18), and Tetric® N-Power Fill 2 (+0.07 ± 0.27) (p ≤ 0.001). In dentin, post-storage Ca/P differed only between Predicta® and Tetric® N-Power Fill 2 (p = 0.006), and recovery did not differ significantly among groups (p = 0.235). On representative SEM micrographs, interfacial gaps were narrowest for Stela (no enamel gap; dentin 6.21 µm) and widest for Predicta® (enamel 11.18 µm; dentin 16.84 µm). Conclusions: Under static storage in mineral-containing artificial saliva, enamel adjacent to Predicta® showed the greatest recovery of the Ca/P ratio, whereas differences in dentin were small. On representative SEM micrographs, Stela showed the closest interfacial adaptation and Predicta® the widest gaps, with wider gaps at dentin than at enamel margins in all systems. Because ion release was not measured, no unrestored control was included, and the storage medium itself supplied calcium and phosphate, these findings describe Ca/P changes at the interface and should not be interpreted as direct evidence of material-driven ion release or of a clinical anticaries benefit.
No takes yet. Share an insight, caveat, or question.
Alqasi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: