Answers are grounded in this paper and cite their sources.
Reliable delineation of underground coal fires requires reproducible criteria for anomaly identification and spatial evaluation capable of distinguishing internal agreement from independent evidence. This study analysed 671 self-potential (SP) observations collected along 28 survey profiles in the Wotuoquan coal-fire area, Xinjiang, China. Profile-specific medians and median absolute deviations were used to calculate robust z scores (RZ), and observations with ∣RZ∣≥2.5 were classified as candidate anomalies. Along-profile adjacency, multisource polygon overlap, gap-aware within-profile circular-shift tests, false discovery rate correction, and threshold-sensitivity analysis were subsequently applied. The procedure identified 82 candidate observations (12.22%), comprising 53 isolated candidates and 29 continuous candidates forming 13 along-profile segments. Compared with background observations, candidates were enriched within the previously mapped SP anomaly and the integrated coal-fire zone delineated from multisource evidence by 27.16 and 18.88 percentage points, respectively, but were underrepresented within aeromagnetic anomalies by 18.21 percentage points. Because the mapped SP and multisource-interpreted boundaries incorporate SP information, the two enrichments quantify internal agreement, whereas the aeromagnetic depletion constitutes the significant SP-independent result; all three relationships remained significant after multiple-testing correction (q = 0.00233). The thermal-infrared anomalies and the external aeromagnetic–thermal core contained too few stations (inside-zone proportions of 1.22% versus 0.85% for the thermal-infrared anomalies, and a single candidate for the external core) for adequate statistical power, so the absence of significant correspondence in these zones reflects limited detectability rather than demonstrated disassociation. The directions and statistical significance of the principal effects remained stable across |RZ| thresholds ranging from 2.00 to 3.00. These results indicate that profile-wise robust standardization can provide a reproducible screening approach for SP surveys. However, the contrasting spatial patterns of SP, aeromagnetic, and thermal-infrared anomalies require process-based interpretation and independent field verification.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: