Key result
Balloon pulmonary valvuloplasty reduces peak RV-PA gradient by ~40 mmHg in repaired TOF.
Why the study?
Residual valvular pulmonary stenosis late after complete repair of tetralogy of Fallot is uncommon, and experience with balloon pulmonary valvuloplasty in this setting is limited.
Does single-balloon pulmonary valvuloplasty improve haemodynamics and symptoms in an adult patient with severe late residual valvular pulmonary stenosis following tetralogy of Fallot repair?
Case Report (n=1)
No
Does single-balloon pulmonary valvuloplasty improve haemodynamics and symptoms in an adult patient with severe late residual valvular pulmonary stenosis following tetralogy of Fallot repair?
In selected patients with repaired tetralogy of Fallot and predominantly valvular residual pulmonary stenosis, balloon pulmonary valvuloplasty can safely provide substantial haemodynamic and symptomatic improvement and may defer repeat surgery.
Answers are grounded in this paper and cite their sources.
BPV may be feasible for rare late residual PS after TOF repair; leaves open need for prospective data before clinical adoption.
Residual valvular pulmonary stenosis late after complete repair of tetralogy of Fallot (TOF) is uncommon, and experience with balloon pulmonary valvuloplasty (BPV) in this setting is limited. A 23-year-old man who had undergone TOF repair at four years of age presented with a one-year history of progressive exertional dyspnoea (New York Heart Association class II) and atypical chest pain. Transthoracic echocardiography showed a peak instantaneous right ventricular (RV)-to-pulmonary artery gradient of 106 mmHg and impaired RV systolic function, with a tricuspid annular plane systolic excursion (TAPSE) of 10 mm. Cardiac catheterization showed an RV systolic pressure of 97 mmHg (RV-to-systemic pressure ratio 0.80), a peak-to-peak gradient of 70 mmHg and a doming pulmonary valve without significant subvalvular obstruction. Single-balloon valvuloplasty with an 18-mm balloon reduced the RV systolic pressure to 60 mmHg (ratio 0.44) and the peak-to-peak gradient to 30 mmHg, with only mild pulmonary regurgitation. Before discharge, the Doppler gradient was 40 mmHg, TAPSE had improved to 14 mm and his symptoms had improved. In selected patients with repaired TOF whose residual obstruction is predominantly valvular, BPV can provide substantial haemodynamic and symptomatic benefit and may defer repeat surgery. Accurate localization of the obstruction and conservative balloon sizing are essential.
No takes yet. Share an insight, caveat, or question.
Mahajan et al. (2026) conducted a case report in Severe late residual pulmonary valve stenosis following tetralogy of Fallot repair (n=1). Balloon pulmonary valvuloplasty (18 x 40 mm Atlas Gold balloon, balloon-to-annulus ratio 1.12) vs. Pre-procedure baseline was evaluated on Peak-to-peak right ventricular-to-pulmonary artery systolic gradient on cardiac catheterization (mmHg). Balloon pulmonary valvuloplasty reduced the catheter peak-to-peak RV-PA gradient from 70 to 30 mmHg and pre-discharge Doppler gradient from 106 to 40 mmHg in a patient with repaired TOF.
Synapse has enriched 10 related papers. Consider them for comparative context: