Key result
EPSS yields ~12-point lower pretraining LVEF error than Teichholz methods, despite limits in severe dysfunction.
Why the study?
The comparative accuracy of E-point septal separation (EPSS) and Teichholz-derived calculations for bedside LVEF estimation when performed by noncardiologist emergency department physicians remained unclear.
Does focused hands-on ultrasound training improve the accuracy and efficiency of EPSS and Teichholz-based LVEF assessment by emergency department physicians compared to the Simpson biplane reference standard?
Does focused hands-on ultrasound training improve the accuracy and efficiency of EPSS and Teichholz-based LVEF assessment by emergency department physicians compared to the Simpson biplane reference standard?
For emergency physicians performing bedside LVEF assessment, EPSS is faster and yields higher confidence than Teichholz methods, with comparable post-training accuracy in preserved and moderately reduced LVEF, though potentially less accurate in severely reduced LVEF.
Answers are grounded in this paper and cite their sources.
Simulation training may enhance noncardiologist EPSS/Teichholz LVEF estimates; leaves open clinical accuracy versus cardiology reference standards.
Background Point-of-care ultrasound (POCUS) enables rapid bedside estimation of left ventricular ejection fraction (LVEF) in the emergency department. Among quantitative methods, E-point septal separation (EPSS) and Teichholz-derived calculations are commonly used; however, their comparative accuracy when performed by noncardiologist clinicians remains unclear. Objective This study aimed to compare the accuracy and efficiency of EPSS and Teichholz-based methods for LVEF assessment by emergency department physicians, using the Simpson biplane method as the reference standard. Methods We conducted a prospective pre-post interventional study using standardized patients (SPs) at a university simulation training unit (March 2025). Following prerecorded lectures and demonstration videos, emergency department physicians (n=26) measured LVEF using three bedside methods—EPSS, Teichholz long-axis, and Teichholz short-axis—before and after a focused hands-on training session including supervised image acquisition and guided LVEF measurement. Five SPs with cardiologist-confirmed LVEF values ranging from 16% to 73% were used across the study assessments. The primary outcome was the absolute difference between participant-measured and reference LVEF. Secondary outcomes included time-to-completion and participant-reported confidence for each method. Results Before training, EPSS demonstrated a significantly lower absolute error (median 5 percentage points, IQR 3-13) compared with Teichholz long-axis (17 percentage points, IQR 9-27) and Teichholz short-axis (13 percentage points, IQR 4-24) methods (P=.009). EPSS also required less time (median 73 seconds, IQR 53-121) than Teichholz long-axis (150 seconds, IQR 103-200) and Teichholz short-axis (100 seconds, IQR 67-184) (P=.02). After training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment (P=.93). In the posttraining reduced-LVEF assessment, no statistically significant difference in absolute LVEF error was detected among methods in the SP with an LVEF of 48% (P=.48). In contrast, in the single SP with an LVEF of 16%, absolute LVEF error differed significantly among methods (P=.008), with greater error for EPSS (median 30.5 percentage points) than for Teichholz long-axis (11 percentage points) and Teichholz short-axis (8 percentage points). EPSS remained the fastest technique in preserved (62 seconds; P<.001) and reduced LVEF cases (79 seconds; P<.001). Confidence scores improved across all methods, with EPSS demonstrating the highest median posttraining confidence (P=.01). Greater variability in EPSS measurements was observed in reduced LVEF, with a mean bias of −16 (SD 23) percentage points and wide 95% limits of agreement from −61.1 to 29.1. Conclusions Following focused ultrasound training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment or in the SP with an LVEF of 48%. However, EPSS demonstrated greater error than both Teichholz methods in the single SP with an LVEF of 16%, a case-specific finding that should be considered hypothesis-generating. EPSS required less time to perform and was associated with higher learner confidence. Trial Registration Thai Clinical Trials Registry TCTR20250123008; https://tinyurl.com/3kphcru3
No takes yet. Share an insight, caveat, or question.
Tangpaisarn et al. (2026) studied Left ventricular ejection fraction assessment via point-of-care ultrasound (n=26). E-point septal separation (EPSS) and focused hands-on POCUS training vs. Teichholz long-axis and Teichholz short-axis methods (referenced against Simpson biplane method) was evaluated on Absolute difference between participant-measured and reference LVEF (p=0.009). EPSS had lower pretraining LVEF error than Teichholz methods, though posttraining error was higher in severe LV dysfunction.