Key result
Adding pulse wave velocity to blood pressure fails to improve hypertension classification performance.
Why the study?
Conventional blood pressure measurements may fail to detect previously unrecognized hypertension, and pulse wave velocity could provide complementary vascular information in a decision tree model for opportunistic identification of isolated hypertension.
Does a decision tree algorithm integrating pulse wave velocity with systolic and diastolic blood pressure improve the opportunistic identification of isolated hypertension in adults compared to blood pressure measurements alone?
Cross-Sectional (n=765)
No
Does a decision tree algorithm integrating pulse wave velocity with systolic and diastolic blood pressure improve the opportunistic identification of isolated hypertension in adults compared to blood pressure measurements alone?
Integrating pulse wave velocity with conventional office blood pressure measurements in a decision tree algorithm may assist in the opportunistic identification of isolated hypertension, although out-of-fold sensitivity analysis did not show a material improvement in macro ROC-AUC.
Answers are grounded in this paper and cite their sources.
PWV addition to BP decision tree yielded no out-of-fold AUC gain; leaves open incremental value of arterial stiffness markers in hypertension phenotyping.
Background/Objectives Current hypertension (HTN) identification relies primarily on conventional blood pressure measurements, which may fail to identify individuals with previously unrecognized HTN. Pulse wave velocity (PWv), an established marker of arterial stiffness, may provide complementary information on vascular status. This study aimed to develop a clinically applicable classification model derived from a decision tree model that integrates systolic blood pressure (SBP), diastolic blood pressure (DBP), and PWv for the opportunistic identification of isolated HTN. Methods A total of 765 adults were classified as “apparently healthy”, “isolated HTN”, or “HTN” on the basis of medical history, antihypertensive treatment, and blood pressure measurements. A supervised decision tree model incorporating SBP, DBP, and PWv was developed to derive a clinically applicable classification model. Model performance was evaluated using classification metrics, confusion matrices, and the area under the receiver operating characteristic curve (AUC). Sex specific models have also been developed to explore potential differences in classification thresholds. Results DBP was identified as the root node of the decision tree, with an initial threshold of 77.75 mmHg, followed by SBP at a threshold of 130.25 mmHg. PWv contributed to classification at multiple subsequent nodes, with thresholds ranging from 7.35 to 10.65 m/s. Sequential integration of DBP, SBP, and PWv enabled discrimination among apparently healthy individuals and those with isolated HTN or established HTN. Sex specific models showed broadly similar hierarchical structures, although the optimal threshold differed between males and females. Conclusion The integration of PWv with conventional blood pressure measurements may facilitate the opportunistic classification of isolated HTN. Although comparative analyses showed improved discrimination with PWv, an out of fold sensitivity analysis did not demonstrate a material improvement in macro ROC-AUC. Further studies are needed to establish its independent incremental value.
No takes yet. Share an insight, caveat, or question.
Martínez-Cifuentes et al. (2026) conducted a cross-sectional in Hypertension and isolated hypertension (n=765). Pulse wave velocity (PWv) integrated with systolic and diastolic blood pressure in a decision tree classification model vs. Conventional blood pressure measurements (SBP and DBP) alone was evaluated on Multiclass classification accuracy and macro ROC-AUC for hypertension status (apparently healthy, isolated hypertension, established hypertension). A decision tree integrating pulse wave velocity with blood pressure achieved 81.3% accuracy for classifying hypertension status, but did not improve out-of-fold AUC.
Synapse has enriched 10 related papers. Consider them for comparative context: