Answers are grounded in this paper and cite their sources.
During coal mine tunnel excavation, gas emissions and dust generation occur simultaneously, creating a coupled dust-gas pollution environment. Under conventional forced ventilation systems, pollutants spread along the airflow and contaminate the entire tunnel, whereas exhaust ventilation systems extract pollutants at the source through negative pressure. However, the coupled dust-gas pollution mechanism and gas accumulation characteristics remain unclear. This study investigates the dispersion process and pollution mechanism under exhaust ventilation compared with forced ventilation, clarifying its advantages and potential risks in pollutant control, and examines the influence of gas on dust pollution behavior. The results indicate that exhaust ventilation confines the pollution ranges of dust and gas to within 8 m and 5.5 m from the excavation face, respectively. Gas removal begins earlier under exhaust ventilation than under forced ventilation, and after 60 s, the extraction rate exceeds the release rate, but the peak gas mass concentration at the roof reaches 3.69%. In gas-containing tunnels, the dust pollution range is larger than that in gas-free tunnels, with gas primarily affecting respirable particles below 10 μ m.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: