Answers are grounded in this paper and cite their sources.
This study evaluates nine combinations of glazing and fixed horizontal overhangs (C1–C9) for a south-facing educational drawing hall in New Damietta, Egypt. On-site measurements of indoor air temperature were compared with simulations over six independent occupied monitoring days. The mean absolute error was 2.31°C and the root mean square error was 2.61°C, with a systematic warm bias that limits interpretation of absolute thermal conditions. Annual daylight performance was assessed by spatial daylight autonomy (sDA), annual sunlight exposure (ASE), and useful daylight illuminance (UDI). ASE was converted from DesignBuilder's passing-area output to conventional exposed area. A 1.00 m wide horizontal overhang, measured as its outward projection from the façade, reduced ASE exposure by 46.63–47.97% within each glazing family, although every case remained above the 10% reference limit. The decision method scores cooling demand alone in the energy domain, avoiding double counting of solar gains and cooling response. C9, comprising low-emissivity, argon-filled double glazing with a 1.00 m wide overhang, scored 97.42/100 and ranked first in all 45 tested category-weight combinations; its narrowest lead was 2.07 points. This identifies a stable comparative candidate within the tested matrix, rather than a universal optimum. Daylight predictions lack field validation, view-dependent glare remains unresolved, and the thermal evaluation does not establish equipment-level accuracy.
No takes yet. Share an insight, caveat, or question.
Sameh Ahmed Qadry (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: