Answers are grounded in this paper and cite their sources.
Total hydrogen inventory need not determine bounded-horizon station-side serviceability in a pressure-differentiated cascade. We examine this state-sufficiency question using a specified isothermal Noble–Abel three-bank model and a deterministic 24-part allocation lattice containing 221 pressure-feasible states. Two extremal states in the 55-state medium-inventory group each contain 328.418 kg, but their one-hour serviceable hydrogen reserves, SRH60, are 24.000 and 54.237 kg. Their 30.237 kg difference is a model-bounded counterexample, not an estimate of operational prevalence. In a completed design-model sensitivity test, common multipliers of 0.8, 1.0 and 1.2 on the three-bank discharge caps give fixed-pair gaps of 25.600, 30.237 and 33.837 kg. The counterexample persists in these settings, but other equal-inventory pairs exhibit heterogeneous responses and ordering reversals. Composition-aware regression increases descriptive R2 from 0.158 to 0.400, without establishing strong predictive performance. The existing four-bin test distinguishes equal-total 20 kg demand profiles, and the separate preparation/service test identifies 6–26 kg of pre-positioning for the low-reserve state at 30–50 kg requests, versus none for the high-reserve state. The results concern the specified station-side model; they do not validate equipment operating ranges, actual vehicle-received mass, field occurrence frequency or universal cost benefits.
No takes yet. Share an insight, caveat, or question.
He et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: