Answers are grounded in this paper and cite their sources.
Lead-free piezoelectric ceramics are being investigated for resonant actuators in response to environmental restrictions on lead-containing materials. This study combines the fabrication and structural, microstructural, dielectric, ferroelectric, and electromechanical characterization of (K0.44Na0.52Li0.04)(Nb0.86Ta0.10Sb0.04)O3 (KNL–NTS) with a preliminary finite-element comparison with APC-880, a commercial hard PZT ceramic. Constitutive parameters identified from the impedance response of poled ceramic disks were implemented in a simplified toothless annular stator model. Under identical geometry, electrical excitation, mechanically free boundary conditions, and room-temperature assumptions, the model predicted maximum displacement amplitudes of approximately 2.6 µm at 45 kHz for KNL–NTS and 3.8 µm at 36 kHz for APC-880. The corresponding estimated peak surface velocities were 0.73 and 0.86 m·s−1. These unloaded numerical results quantify the relative electromechanical response of the two materials, but do not represent experimentally validated motor performance because teeth, rotor preload, frictional contact, machining effects, and self-heating were not included. The results support further investigation of KNL–NTS in fabricated and experimentally validated ultrasonic stators.
No takes yet. Share an insight, caveat, or question.
Madrigal et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: