Answers are grounded in this paper and cite their sources.
Reliable fatigue‐life assessment is essential to the structural integrity of engineering components subjected to multiaxial loading. This study develops a mechanics‐constrained extension of the Classical Sines equivalent‐stress descriptor for proportional axial–torsional fatigue. The formulation retains the distortional‐amplitude and hydrostatic mean‐stress terms while introducing scalar measures of axial–torsional interaction and mean deviatoric shear, and is coupled with a Basquin‐type life relation. Validation is performed on S355 structural steel, 7075‐T651 aluminum alloy, 18Ni300 maraging steel, and CuZn37 brass using log 10 (N)‐based error metrics, k ‐fold cross‐validation, and regime‐wise comparisons with Classical Sines, Dang Van, von Mises, and Fatemi–Socie formulations. The proposed descriptor improves out‐of‐fold prediction for the principal high‐cycle‐fatigue datasets, particularly under combined loading with mean stresses, while preserving a compact and interpretable analytical structure. Its present validity is limited to proportional axial–torsional conditions.
No takes yet. Share an insight, caveat, or question.
Layes et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: